Why 99.9% CO₂ purity is not enough for food and beverage use

25 November 2026

A CO₂ purity of 99.9% tells only part of the story. Food and beverage applications also require specific impurity limits, source qualification and documented quality control.

Key takeaways

  • Industry specifications for food and beverage grade CO₂ commonly require at least 99.9% purity, but that is only the headline figure.
  • The specification also sets limits for impurities, including sulphur compounds such as hydrogen sulphide (H₂S), moisture (20 ppm) and oxygen (30 ppm).
  • The 0.1% that 99.9% leaves open is about 1,000 ppm, while individual impurity limits can be thousands of times lower.
  • Food-grade status also depends on source qualification and documented quality procedures, not on bulk purity alone.
  • Which impurities are plausible depends on where the CO₂ comes from, for example, fermentation, biogas upgrading or the original CO₂ supply and collection process at a dry ice plant.
  • The terms food grade and beverage grade are sometimes used interchangeably, so the agreed specification matters more than the label.
  • A single purity figure describes the bulk of the gas. The specification defines additional limits for impurities.

The number everyone quotes

Ask what makes CO₂ suitable for food and drinks, and the first answer is usually a percentage: at least 99.9% purity. It is a handy headline figure, widely used in industry specifications such as those published by EIGA and ISBT. It tells you that at most one part in a thousand of the gas is something other than CO₂.

The European E290 food additive specification actually sets a minimum CO₂ content of 99%, but industry and customer requirements can be stricter. The trouble starts with what the remaining fraction can contain. At 99.9% purity, 0.1% is about 1,000 ppm. A gas can meet that figure and still carry a contaminant at a concentration far above its individual limit.

What the specification really limits

The ISBT guidelines and EIGA Doc 70/26, which the industry widely uses as reference points, do not stop at a purity percentage. They address individual impurities, source qualification and quality control. Three examples from EIGA 70/26 show how tight the limits are:

  • Total sulphur, including H₂S: 0.1 ppm, expressed as sulphur and excluding SO₂
  • Moisture: 20 ppm
  • Oxygen: 30 ppm

Take hydrogen sulphide (H₂S), with its distinctive rotten-egg smell. Our noses can detect it at very low concentrations in air. That helps explain why food and beverage specifications also address odour, even when the overall CO₂ purity looks high.

H₂S falls under the total sulphur limit of 0.1 ppm, which is 10,000 times lower than the 1,000 ppm the headline figure leaves open. A purity analysis that only confirms 99.9% cannot demonstrate compliance at that level.

The limits also cover very different kinds of components. Moisture and oxygen can originate from the incoming gas or be affected by drying, process conditions and air ingress. Organic trace compounds such as aromatic hydrocarbons depend strongly on the original gas source and its treatment.

Why the source matters as much as the analysis

This is where source qualification comes in. Before CO₂ from a given source can be called food grade, someone has to ask which impurities that source could plausibly contain, how often they are measured and what happens when a result drifts. That means documented quality procedures, not a single good certificate.

The same logic applies across very different sources. A brewery capturing fermentation CO₂, a dry ice producer reliquefying recovered process gas and a biogas plant processing CO₂-rich off-gas each have different quality considerations. For biogas upgrading, methane, oxygen, nitrogen, moisture and trace contaminants all depend on the feedstock and on the upgrading technology upstream. The final liquid can be very pure, and the route it took still has to be understood and documented.

At Solveno Technologies, we develop CO₂ recovery and liquefaction systems for biogas upgrading and dry ice production. For biogas applications, the required purification process depends on the actual off-gas composition and the intended liquid CO₂ specification. Bulk purity above 99.9% is only part of that assessment. The relevant impurities, source qualification and quality procedures must also be considered.

For further technical background, see our guide to biogas upgrading technologies and their impact on CO₂ recovery.

Food grade versus beverage grade

A frequently asked question is whether food grade and beverage grade are the same thing. In everyday use the two terms are often interchanged, but they do not replace a defined specification. EIGA provides guidance for both food and beverage applications, while the European E290 specification defines regulatory requirements for CO₂ used as a food additive. Customers may also impose additional requirements.

Whether a supplier's food-grade CO₂ meets a brewery's expectations therefore depends on the specification that was actually agreed. The documented limits, analysis frequency and source qualification tell you far more than the label alone.

One number, one gas, one specification

Purity percentages are attractive because they compress a gas into one figure. A specification does the opposite: it identifies limits for sulphur compounds, moisture, oxygen and other components that a percentage quietly folds into the last tenth of a percent. The single figure describes the bulk of the gas. The specification defines the additional requirements that determine whether the CO₂ is suitable for its intended use.

For the applicable European regulatory requirements, see Commission Regulation (EU) No 231/2012, including the E290 carbon dioxide specification.

Frequently asked questions

Is 99.9% CO₂ purity enough to call a gas food grade?

No. While 99.9% purity is commonly required by industry specifications such as EIGA and ISBT, bulk purity alone is insufficient. Individual impurity limits, source qualification and documented quality procedures must also be considered.

Which impurities does the specification limit?

EIGA Doc 70/26 sets limits for various impurities, including sulphur compounds such as H₂S, moisture at 20 ppm and oxygen at 30 ppm. Additional source-specific impurities must be assessed where relevant.

How much room does 99.9% purity leave for other components?

0.1%, which is about 1,000 ppm in total. Individual limits such as 20 ppm for moisture are far tighter than that overall allowance, which is why the purity figure alone cannot confirm compliance.

What is the difference between food grade and beverage grade CO₂?

The terms are often used interchangeably. EIGA provides specifications for both food and beverage applications, while European E290 regulations define requirements for CO₂ used as a food additive. The exact requirements depend on the applicable standard and the agreed customer specification.

Why does the origin of the CO₂ matter for quality?

Different sources carry different potential impurities. In biogas upgrading, for example, methane, oxygen, nitrogen, moisture and trace contaminants depend on the feedstock and upgrading technology. That is why source qualification and documented quality procedures are essential for food-grade applications.

Biogas upgrading technologies and their impact on CO₂ recovery

Read more

Energy-efficient CO₂ liquefaction for biogas and dry ice

Read more

Carbon Brussels

Read more
keyboard_arrow_up