CO₂ Recovery from dry ice production

31 October 2026

Recover CO₂ gas released during dry ice production, reliquefy it and return it for reuse. Solveno Technologies supplies modular systems designed around your production equipment and operating conditions.

CO₂ recovery for dry ice production

Dry ice production converts liquid CO₂ into solid CO₂, but also releases a substantial stream of gaseous CO₂. Rather than venting this gas, a recovery unit can collect it, compress it and reliquefy it for reuse in the plant. Solveno Technologies develops modular recovery systems specifically for this application.

How does CO₂ recovery work in dry ice production?

A dry ice CO₂ recovery system processes the gas released by dry ice presses or pelletizers and returns it as liquid CO₂, provided the recovered product meets the plant's quality requirements. The main steps are:

  1. Collect the gas. CO₂ gas from the dry ice machines is routed through a collection header to the recovery unit. The collection pressure and allowable backpressure must be compatible with the production equipment.
  2. Check and condition the gas. The inlet gas is assessed for moisture and other impurities. Drying or other treatment is included where required by the gas quality and downstream equipment.
  3. Compress and reliquefy. The gas is compressed and cooled until it can be returned to the liquid phase. Solveno's recovery concept uses CO₂ (R744) in a separate, closed-loop refrigeration circuit.
  4. Return the liquid CO₂. Recovered liquid is routed back to the appropriate storage or production interface. Tank pressure, temperature and product quality are considered in the integration.

CO₂ recovery system for a dry ice production plant

How much CO₂ can be recovered from a dry ice plant?

The recoverable flow depends on the dry ice production process and the gas that can actually be collected. It cannot be determined from the dry ice production capacity alone. A site-specific mass balance should account for liquid CO₂ entering the machines, solid dry ice output, gas released and any other losses.

The main design inputs are:

  • Production profile: dry ice output, number of machines, simultaneous operation and annual running hours.
  • Gas flow: typical, minimum and peak flow to the recovery unit, including starts, stops and partial-load operation.
  • Gas pressure and temperature: conditions at the collection point and the backpressure permitted by the dry ice machines.
  • Pipework: distance to the recovery unit, insulation, pressure losses and available installation space.
  • Gas and liquid quality: CO₂ composition, moisture content and the specification required for reuse.

A stated recovery capacity in kg/h therefore refers to defined operating conditions, not necessarily to every possible combination of inlet pressure, temperature and production load.

Electricity consumption and recovery economics

For a dry ice producer, the main economic benefit is the reduction in liquid CO₂ that must be replenished. The value of recovery depends on the amount of usable liquid CO₂ returned, the cost of replacement CO₂ and the operating cost of the recovery system.

Electricity consumption should be compared in kWh per tonne of recovered liquid CO₂, using the same system boundary. A complete comparison accounts for compression, refrigeration and relevant auxiliary equipment rather than compressor power alone. Gas collection pressure, production load and ambient conditions can materially change the result.

For an initial business case, we examine the recoverable CO₂ volume, annual operating hours, electricity price, CO₂ replacement cost and maintenance requirements. Read our guide to energy-efficient CO₂ liquefaction for a worked explanation of electricity costs and how to compare complete-system consumption.

Discuss recovery at your plant

CO₂ recovery systems for dry ice producers

Solveno offers modular, containerized systems sized for the gas flow and operating conditions of the dry ice plant. The CR-35 and CR-17 below illustrate two recovery capacities; the appropriate configuration is selected from the actual production profile and installation requirements.

CR-35

Solveno CR-35 CO₂ recovery unit

For larger gas flows from dry ice production, including installations with multiple machines.

Recovery capacity
Up to 3,500 kg/h CO₂ under specified conditions

Product quality
Subject to incoming gas quality and required conditioning

Container configuration
1 × 40 ft container or 2 × 20 ft containers

CR-17

Solveno CR-17 CO₂ recovery unit

For lower gas flows where a smaller recovery system matches the production profile.

Recovery capacity
Up to 1,750 kg/h CO₂ under specified conditions

Product quality
Subject to incoming gas quality and required conditioning

Container configuration
1 × 30 ft container or 2 × 20 ft containers

See the CO₂ recovery systems for dry ice production for other standard configurations and available product sheets.

Explore recovery systems

Integration into an existing dry ice production plant

Dry ice CO₂ recovery can be considered for new production lines or as a retrofit. The recovery unit must be designed around the operating limits of the existing dry ice equipment, not simply connected to an available vent line.

  • Collection pressure: the permitted backpressure and pressure fluctuations at the dry ice machines are established before selecting the recovery arrangement.
  • Gas pipework: routing and insulation are assessed to manage gas temperature, pressure losses and integration with existing equipment.
  • Return to liquid storage: the receiving tank's pressure, temperature and connection arrangement are included in the design.
  • Variable operation: the control philosophy reflects changes in gas flow as dry ice machines start, stop or change output.
  • Containerized installation: equipment location, utilities, access and service space are considered alongside the available footprint.

The systems are designed for automated normal operation, with operator supervision and maintenance requirements defined for the project. Using CO₂ as the refrigerant in a closed circuit avoids the need for a separate synthetic refrigerant in that cooling circuit.

CO₂ recovery in operation at IJsfabriek Strombeek

Solveno installed a CR-35 CO₂ recovery unit at IJsfabriek Strombeek in Belgium, where gas released during dry ice production is recovered and reliquefied. The published project reference reports 1,000 tonnes of CO₂ recovered during the first two months of operation. It provides an operating example rather than a performance guarantee for another plant.

See the installation

Frequently asked questions about dry ice CO₂ recovery

Can recovered CO₂ gas be reused to make dry ice?

Yes. Gas collected from dry ice production can be compressed, reliquefied and returned for reuse when it meets the required liquid CO₂ specification. Additional gas treatment may be needed depending on the inlet quality.

How much CO₂ can be recovered per kilogram of dry ice?

There is no single recovery figure that applies to every plant. The amount depends on the production process, gas collection arrangement and operating conditions. We use the plant's CO₂ mass balance and actual gas flow to estimate recoverable quantities.

Does the recovery system automatically produce food-grade CO₂?

No. Recovery and reliquefaction do not, by themselves, certify product quality. The composition and moisture of the collected gas, any required treatment and the intended product specification must be assessed separately.

Can a CO₂ recovery unit be added to existing dry ice machines?

Often, yes, subject to an engineering review. The important checks include allowable backpressure, gas flow, pipework, available utilities and the interface with liquid CO₂ storage.

Is this the same as capturing CO₂ from industrial exhaust gas?

No. Dry ice recovery collects a CO₂-rich stream already released by the dry ice production process. It is not a system for separating CO₂ from dilute flue gas or ambient air.

What determines the electricity consumption of a recovery unit?

The main factors include gas inlet pressure and temperature, gas flow, ambient conditions, refrigeration duty and part-load operation. Compare the complete electrical consumption per tonne of usable recovered liquid CO₂ under the same stated conditions.

Assess CO₂ recovery at your dry ice plant

Share the number and type of dry ice machines, typical production capacity, available off-gas flow or mass balance, gas pressure and temperature, annual operating hours and your liquid CO₂ storage conditions. With these inputs, we can assess a suitable recovery configuration and the information needed for an initial technical and economic evaluation.

Send your plant details

CO₂ Recovery from biogas upgrading

Recover and liquefy the CO₂-rich off-gas from biomethane upgrading into purified liquid CO₂, with methane recovery where relevant.

Read more
keyboard_arrow_up